Model | ACME400-3360 | ACME400-3390 | ACME400-33120 | ACME400-33150 | ACME400-33180 | |
Capacity | 60KVA | 90KVA | 120KVA | 150KVA | 180KVA | |
Input | Voltage | 380(1±15%)V(Continuous fluctuation)/380(1±20%)V(Transient fluctuation, derating use) | ||||
Frequency | 50(1±10%)Hz | |||||
PF | ≥0.96 | |||||
Impulse current |
Soft start, no impact | |||||
Output | Rating voltage | Three phase four wire 115/200V | ||||
Rating frequency | 400Hz | |||||
Voltage stability | ± 1% FS (note FS means full scale) | |||||
Voltage adjust range | ≥115*(1±15%)V | |||||
Frequency stability | ±0.01% | |||||
Dynamic characteristics | Voltage overshoot < 8%, recovery time < 10ms, frequency overshoot < 0.1%, recovery time < 10ms | |||||
Harmonic content | Total harmonic content < 1.5%, single harmonic content < 1% (linear load) | |||||
Peak coefficient of voltage | 1.414±0.05 | |||||
Voltage modulation | < 1%, the modulation spectrum meets the requirements of MH / t6018 and iso6858 | |||||
Three phase unbalance | Phase voltage difference < 2V | |||||
Phase | 120±1˚(no load or balanced load) / 120±1.5˚(1 / 3 unbalanced load) | |||||
Voltage regulation | 115V ± 1V (symmetrical load changes within 0-100%), 115V ± 1.5V (30% asymmetrical load) | |||||
Adaptive load PF | 0.6 (lagging) - 0.95 (leading) | |||||
Voltage compensation | Maximum compensation 10V | |||||
Comprehensive characteristics | Overload ability | 110%, continuous operation; 125%, 600s; 150%, 300s; 200%, 60s; 300%, 1.5s; 400%, 1s | ||||
Protection function | Input over-voltage, under voltage, phase loss; output open circuit, EF interlock protection, poor plug-in protection, internal fault Output short circuit, overload, overvoltage, Underfrequency, phase failure or phase sequence error, inverter overcurrent, internal overheating |
|||||
Operation display | VFD | |||||
Electromagnetic compatibility | Meet the requirements of iec61000-6-2, iec61000-6-4, etc | |||||
Efficiency | Rated condition | ≥94% | ||||
Standby power | <50W | |||||
No load power consumption | <2kw | |||||
Reliability and life | MTBF | ≥1*105h | ||||
MTTR | ≤20min | |||||
Service life | ≥20 years | |||||
Environment | Working temperature | -40ºC-70ºC | ||||
Humidity | ≤95%(25ºC) | |||||
Storage temperature | -50ºC-55ºC | |||||
Noise | <60dB(A),within 1m, height 1.5m measurement | |||||
Protection level | IP20/IP55 | |||||
Size(Wmm*Dmm*Hmm) | 1000*900*600(Horizontal) 610*1000*1510(Vertical) |
1600*1100*700(Horizontal) 660*1000*1785(Vertical) |
||||
Trailer W*H*D(mm) | 1985*1385*1090(trailer inclusive) | 1400*1400*2760(Trailer inclusive) | ||||