Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 20000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | ACME400-3390 | |
Input | Phase number | Three phase three wire+PE |
Voltage | 380V/400V±15% | |
Frequency | 45~63Hz | |
Line current Distortion |
8.5% | |
PF | >96%(100% load) | |
Impulse current | None, with soft start function | |
Output | Phase number | Three phase four wire |
Output voltage | 3 × 200/115V | |
Output power | 0~90KVA | |
PF | 0.7 lagging, 0.95 leading | |
Voltage regulation | <0.5% (balanced load or 30% unbalanced load) | |
Total harmonic content | <1.5% linear load <2% non-linear load according to ISO1540 |
|
CF | 1.414±3% | |
Voltage modulation | <1.0% (typical<0.5%) | |
Phase symmetry | 120 ° ± 1 ° (balanced load); 120 ° ± 2 ° (30% unbalanced load) |
|
Frequency | 400Hz±0.1% | |
Output current | Below 20% of rated current: 2% of range Above 20% of rated current: 5% of range |
|
Overload |
>100% overload can work for 600 seconds >125% overload can work for 60 seconds >150% overload can work for 30 seconds >200% overload can work for 10 seconds >300% overload can work for 1 seconds >400% overload immediate alarm |
|
Efficiency | Total efficiency | cosΦ=0.8 full load,>0.93 |
Standby power | <50W(fan stopped) | |
Set | Voltage output | 100-130V |
Voltage compensation | 0-9V | |
Delay waiting | 0-15mins | |
Time | Year, month, day, hour, minute, second | |
Interlocking power supply | Open/Bypass | |
Fan | Constant speed/conventional | |
Fault record | Review/Clear | |
Power recording | Review/Clear | |
Protect | Input overvoltage and undervoltage protection, input phase sequence protection | |
Critical unit overheat protection | ||
Internal power supply monitoring of each power supply | ||
Output overvoltage and undervoltage (refer to MH/T6018 standard) | ||
Output overload protection, output short circuit protection | ||
Environment | Working temperature | -40ºC-+60ºC |
Relative humidity | 10%-100%(non condensing) | |
Noise level | <65dbB(A)(1m),usually 60dbB(A) | |
Protection standards | IP55(outdoor operation) | |
Service life | Service life | >25 years |
Mean time between failures | Inverter section >25,000 hours | |
Ventilation section >100,000 hours | ||
Mean time to repair (MTTR) | <20mins |
|
Remark | The testing conditions for setting errors/measuring trial errors are (25 ºC± 5 ºC); |