Customization: | Available |
---|---|
Output Type: | DC |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 10000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Performance characteristics
1. Small volume, light weight, high efficiency, reliable quality and stable performance.
2. The input and output are isolated, and the power operation is safer.
3. It has constant voltage and constant current output mode; The output voltage and output current can be adjusted in full range.
4. It has input multilevel filter circuit to reduce harmonic interference to power grid.
5. The double closed-loop control circuit has fast response and stable output.
6. The multi short circuit protection circuit is used to ensure the reliability of high voltage power supply in the state of frequent short circuit.
7. The whole bridge phase shifting soft switch technology is adopted, and the overall efficiency is higher than 90%.
8. With RS485 communication interface, Modbus RTU communication protocol is adopted.
9. It has external analog interface, which can realize external detection of power status and control power output.
10. Redundancy technology: aiys high power high voltage power system can cut off any one or a group of single machine at any time without affecting the stable operation of the whole power system when redundant machine equipment is configured. The application of this technology improves the stability of some systems that cannot be cut off.
11. Protection mode: over voltage protection, over-current protection, over temperature protection, phase loss protection, short circuit protection, overload protection, input undervoltage and overvoltage protection
Unique technology
1. Multiple anti ignition short circuit protection to ensure the reliability of the machine
(1) the power supply has a current uprush suppression circuit, which can effectively suppress the current uprush of several thousand amperes at the moment of high voltage output short circuit.
(2) when the high-voltage output is short circuited, the instantaneous high-voltage interference will be generated through the ground wire and fed back to the power grid. The special discharge protection circuit of the power supply ensures that other equipment and the power supply itself will not be damaged or disturbed.
(3) short circuit of power supply will cause sudden change of current in the circuit. When the sensitive current detection circuit detects that the current exceeds the set value of protection, it will start the current limiting and power limiting control circuit within 10 microseconds to ensure that the output current is controlled within the set value.
(4) short circuit of power supply will cause high-voltage voltage drop. The voltage drop flash detection circuit detects the ignition short circuit of load at the first time and starts the protection circuit in time.
2. High pressure and low pressure separation design
In order to protect the user's personal safety to the greatest extent, the control level low voltage part and the output level high voltage part are divided into two chassis design. The user's regulating power part is the low voltage cabinet (the maximum voltage is not more than 400V). The high voltage part is completely sealed in the high voltage cabinet, and the machine shell is grounded, so as to completely isolate the high voltage part from the operator.
3. Reliability assurance of core devices
Infineon IGBT module and MICROSEMI rectifier module are adopted as the core components of the power supply. The modules are widely used in various industries in the market, with high operation stability, good versatility and reliability guaranteed.
Technique parameters:
Operation mode | Automatic transition of CV and CC |
Input voltage | AC380V±10%,50Hz±10% |
Output | Approximate 0 ~ rated voltage value continuously adjustable |
Approximate 0 ~ rated current value continuously adjustable | |
Voltage stabilization accuracy | Source effect: ≤ 0.2% of rated value (only due to input source voltage variation ±10%, output voltage change rate) |
Time drift: ≤ 0.2% of rated value (only the change rate of output voltage caused by continuous working time more than 8 hours) | |
Load effect: ≤ 0.2% rated value (only the change rate of output voltage caused by the change of output current from zero to rated value) | |
Steady current accuracy | Source effect: ≤ 0.1% of rated value (only due to input source voltage variation ±10%, output voltage Change rate) |
Time drift: ≤ 0.3% of rated value (only output voltage change rate caused by continuous working time more than 8 hours) | |
Load effect: ≤ 0.2% rated value (only the change rate of output voltage caused by the change of output current from zero to rated value) | |
Output ripple | Under voltage stabilization: ≤ 0.3% + 10mV (measured at 80% ~ 100% rated output) |
Efficiency | ≥95% |
Setting of output voltage and current | Ten turn potentiometer, external 0-10V or 4-20mA control signal |
Power factor | cosΦ= 0.95 |
Output stability | ≤0.3%(change rate of output voltage every 8 hours after starting up for half an hour) |
Output voltage regulation range | Approximately 0 ~ the rated voltage is continuously adjustable |
Output current regulation range | Approximately 0 ~ rated current value continuously adjustable |
Protection mode | Overvoltage, overcurrent, overheating and short circuit protection alarm function; The output can be turned off within 10us |
Display mode | LCD |
Display accuracy | 0.01KV; 0.01A(Note: the display accuracy of different specifications of power supply may be different) |
Error of voltage and ammeter of the whole machine | ≤±0.5%(measuring range 50% ~ 100% rated value) |
Intelligent computer control function | It is directly connected with PC through RS232 or 485 interface, and the output voltage and current value are controlled by special software. The working state of power supply can be monitored in real time on the computer to accurately grasp the load characteristics( (optional) |
Overload capacity | Less than 1.2 times of rated current, it still works normally |
Operation mode | Long term full load continuous operation |
Environment | Place of use: indoor use only temperature Temperature: - 20 ºC ~ 40 ºC Air humidity: ≤ 80% |
Handling and installation
(1) The product must be properly transported and stacked according to its weight; do not stand on the product or place heavy objects on it.
(2). Do not use the cable or device connected with the product to be used to drag the product, especially to prevent collision and scratches.
(3). When handling the products, please use the correct tools to prevent damage.
(4), prevent screws, cable fragments or other conductive objects or oil and other combustible objects from entering the machine.
(5) Do not make the machine ventilation blocked, so that the smooth ventilation.
(6) In normal use, the machine must be input according to the identified voltage value.
(7) Do not move any warning signs of the machine without authorization.
(8) Do not enter any object on the machine ventilation, nor no liquid into the machine.
(9) When the machine cannot be used according to the normal use steps, do not try to repair the machine, it must be completed by a professional electrical engineer with equipment experience.
(10) The shell of this device is not waterproof design, and the product should be installed in a place without rain and direct sun exposure.
(11) Product installation and use should pay attention to good ventilation, to avoid the invasion of combustible gases and corrosive substances.
1.4 Wiring
(1) The personnel participating in the wiring and inspection must have the ability to complete this work.
(2) The grounding must be reliable, and the grounding resistance should be less than 1 ohm.
(3) The wiring must be correct and firm, otherwise it may cause misoperation.
(4) The voltage value and positive and negative (+, -) polarity of any wiring plug must comply with the provisions of the manual, otherwise short circuit or permanent damage to the equipment may occur.
(5) The fingers should be kept dry before pulling the switch to prevent electric shock.
(6) the device connection wire can not be damaged, can not be squeezed, otherwise electricity leakage or short circuit may occur.
(7) In order to ensure the normal operation of the power supply, please choose the appropriate power supply wiring and empty open.
Unique Technology
1. Multiple anti-spark short circuit protections ensure machine reliability
(1) The power supply has a current overshoot suppression circuit, which effectively suppresses the current overshoot of several thousand amperes generated by the high voltage output short circuit. rush.
(2) When the high-voltage output is short-circuited, it will generate instantaneous high-voltage interference through the ground wire and feedback to the power grid. The power supply's unique discharge Protection circuits ensure that other devices and the power supply itself are not damaged or disturbed .
(3) A short circuit in the power supply will cause a sudden change in the current in the circuit. The sensitive current detection circuit detects that the current exceeds the protection setting. The current limiting and power limiting control circuit is started within 10 microseconds when the value is reached to ensure that the output current is controlled within the set value.
(4) A short circuit in the power supply will cause a drop in the high voltage. The voltage drop and flash detection circuit will detect the spark of the load immediately. In case of short circuit, the protection circuit is activated in time.
2. High-voltage and low-voltage separation design
In order to protect the user's personal safety to the greatest extent, the power supply will control the low-voltage part of the stage and the high-voltage part of the output stage The power supply is divided into two cabinets, the user-adjustable power supply part is a low-voltage cabinet (the maximum voltage does not exceed 400 V), and the high-voltage part It is completely sealed in the high-voltage casing and the machine casing is grounded, thus completely isolating the high-voltage part from the operator.