Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 60000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | ACME 400-13005 |
ACME 400-13010 |
ACME 400-13030 |
ACME 400-13050 |
ACME 400-13100 |
|||
Capacity | 500VA | 1KVA | 3KVA | 5KVA | 10KVA | |||
Circuit model | IGBT/SPWM | |||||||
Input | phase | single phase | ||||||
voltage | 220V±10% | |||||||
frequency | 50Hz/60Hz/±10% | |||||||
Output | Phase | three phase four wire | ||||||
Waveform | SINE WAVE | |||||||
Voltage | phase voltage | Rated:115V,0-150V Continuing Adjust | ||||||
Wire voltage | Rated:200V,0-260V Continuing Adjust |
|||||||
Load stability | ≤1% | |||||||
Frequency | 400HZ, 300HZ-500HZ Continuing Adjust(can be customized) | |||||||
Frequency stability | Rated frequency≤0.1%;Adjustment range≤0.01% | |||||||
Wave distortion | THD≤3% | |||||||
Phase difference | phase position120°≤±2°,Phase voltage difference<3%rated value | |||||||
Efficiency | ≥80%(100%Load) | |||||||
Reaction time | ≤2mS | |||||||
Display | High precision LED display, Voltage, current, frequency, power and power factor | |||||||
Cooling | Compulsive fan cooling | |||||||
Noise | ≤55dB(1m) | |||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | |||||||
Reliability | MTBF | h1.0*105 h | ||||||
MTTR | 0.5 h | |||||||
Environment | Working temperature/ Relative humidity | -25ºC-55ºC/0-90%(No condensing) | ||||||
Altitude | ≤2000meters |
Model | ACME 400-33150 |
ACME 400-33200 |
ACME 400-33300 |
ACME 400-33450 |
ACME 400-33600 |
||
Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | ||
Circuit model | IGBT/SPWMpulse width adjustment mode | ||||||
Input | Phase | three phase | |||||
Voltage | 380V±10% | ||||||
Frequency | 50Hz/60Hz/±10% | ||||||
Output | Phase | three phase four wire | |||||
Waveform | SINE WAVE | ||||||
Voltage | phase voltage | Rated:115V,0-150V Continuing Adjust | |||||
Wire voltage | Rated:200V,0-260V Continuing Adjust |
||||||
Load stability | ≤1% | ||||||
Frequency | 400HZ, 300HZ-500HZ Continuing Adjust(can be customed) | ||||||
Frequency stability | Rated frequency≤0.1%;Adjustment range≤0.01% | ||||||
Wave distortion | THD≤3% | ||||||
Phase difference | phase position120°≤±2°,Phase voltage difference<3%rated value | ||||||
Efficiency | ≥80%(100%Load) | ||||||
Reaction time | ≤2mS | ||||||
Ammeter display | Precision four-digit LED display lights,Voltage current frequency power and power factor | ||||||
Cooling | Compulsive fan cooling | ||||||
Noise | ≤55dB | ||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | ||||||
Reliability | MTBF | 1.0*105 h | |||||
MTTR | 0.5 h | ||||||
Environment | Working temperature/ Relative humidity | -25ºC-55ºC/0-90%(No condensing) | |||||
Altitude | ≤2000meters |
Model | ACME 400-33750 |
ACME 400-331000 |
ACME 400-331500 |
ACME 400-332000 |
ACME 400-333000 |
||
Capacity | 75KVA | 100KVA | 150KVA | 200KVA | 300KVA | ||
Circuit model | IGBT/SPWMpulse width adjustment mode | ||||||
Input | Phase | three phase | |||||
Voltage | 380V±10% | ||||||
Frequency | 50Hz/60Hz/±10% | ||||||
Output | Phase | three phase four wire | |||||
Waveform | SINE WAVE | ||||||
Voltage | phase voltage | Rated:115V,0-150V Continuing Adjust | |||||
Wire voltage | Rated:200V,0-260V Continuing Adjust |
||||||
Load stability | ≤1% | ||||||
Frequency | 400HZ, 300HZ-500HZ Continuing Adjust(can be customed) | ||||||
Frequency stability | Rated frequency≤0.1%;Adjustment range≤0.01% | ||||||
Wave distortion | THD≤3% | ||||||
Phase difference | phase position120°≤±2°,Phase voltage difference<3%rated value | ||||||
Efficiency | ≥80%(100%Load) | ||||||
Reaction time | ≤2mS | ||||||
Ammeter display | Precision four-digit LED display lights,Voltage current frequency power and power factor | ||||||
Cooling | Compulsive fan cooling | ||||||
Noise | ≤55dB | ||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | ||||||
Reliability | MTBF | h1.0*105 h | |||||
MTTR | 0.5 h | ||||||
Environment | Working temperature/ Relative humidity | -25ºC-55ºC/0-90%(No condensing) | |||||
Altitude | ≤2000meters |