Customization: | Available |
---|---|
Current Type: | AC |
Phase: | Three Phase |
Still deciding? Get samples of US$ 10000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input Voltage | Regulators scope | Three Phase304V-456V,One Phase176V-264V |
Frequency | 50HZ/60HZ | |
Output Voltage | Rated voltage | Phase Voltage 220V,Line Voltage 380V |
Regulators accuracy | ±(1-5)% option(±2.5%for the conventional) | |
Response time | ≤10ms | |
Waveform distortion | Do not produce additional waveform distortion(static) | |
Efficiency | ≥98% | |
Three-phase imbalance |
Automatic three-phase voltage balance | |
Delay output | Again from the first regulator(protective equipment without shocks) | |
Overvoltage | The output voltage of more than 10%(245V),or cut output to bypass uninterrupted | |
Under voltage | The output voltage of less than 10%(195V),or cut output to bypass uninterrupted | |
Protection | Lack of phase | automatically cut |
Overload | Electronic detection, within three minutes overload cut output | |
Short circuit | Dual electronic detection and protection circut breakers | |
Over current | Dual electronic detection and protection circut breakers | |
Bypass | Manual or automatic bypass uninterrupted | |
Lights | Voltage | A,B,C,respectively, with three-phase ABC TRMS figures show |
Current | A,B,C,respectively, with three-phase ABC TRMS figures show | |
Working conditions | Regulators stae/bypass state | |
Abnormal | Over-voltage, under-voltage, overload, fuse fault | |
Work methods | The two regulators are working methods and bypass | |
Overload | Five times the rated current 1 seconds |
Fast response | Twelve high-speed AD collection, collecting 64 points a week-wave, digital processing MCU computing, electronic modules rapid compensstion. |
Multiple adjustment formula can be set | The same tune: When ses with the tune, while AD Acquisition A,B,C the true RMS voltage three-phase conducted average, gives instructions for compensation can effectively improve the imbalance of the three-phase voltage. |
The tune: When set the tune, each three-phase voltage adjustment to ensure the accuracy of three-phase voltages are within the framework of three-phase voltage imbalance in the power grid, we can balance three-phase voltage, Particularly suitable for single-phase load. | |
Automatic judgment: microcomputer automatic analysis should be conducted at the same tune or transferred. | |
Advanced Measurement Technology |
12AD acquisition, digatl filtering and SCM TRMS calculation. |
The adduracy control | Large-scale programmable logic device and MCU with the perfect. |
Human interface | Through touch button operation panel can set various indicators(output voltage regulator accuracy and protection). |
No output waveform Distortion |
Using non-contact switch is switched off, the same frequency, with the wave phase-locked compensation superposition principle. |
Harmonic interference resistance |
True RMS voltage detection. |
Wide Load | Resistive, capacitive, inductive load can adapt. |
Starting ease impact | A first regulator to output. |
Full protection | When there overvoltage, under-voltage, in one second or in the protection of automatic conversion to bypass uninterrupted work, and the lack of sound, overload, short-circuit protection and faul after the sound and light alarm function. |
Voltage and current shows |
Voltage, current figures show that were true RMS. |
Model | Rated Capacity (KVA) | Input voltage range (V) | Output voltage (V) | Rated current (A) | Cabinet Outer Size W*D*H(mm) | Weight (kg) |
ZBW-S10 | 10 | Three phase 304V-456V | Three Phase 380V±7% Can be setup | 15 | 360×610×160 | 140 |
ZBW-S20 | 20 | 30 | 360×610×160 | 160 | ||
ZBW-S30 | 30 | 46 | 360×610×160 | 180 | ||
ZBW-S50 | 50 | 76 | 400×660×880 | 195 | ||
ZBW-S80 | 80 | 121 | 660×660×1500 | 316 | ||
ZBW-S100 | 100 | 152 | 660×660×1500 | 330 | ||
ZBW-S120 | 120 | 182 | 660×660×1500 | 380 | ||
ZBW-S150 | 150 | 228 | 700×700×1600 | 450 | ||
ZBW-S180 | 180 | 273 | 700×700×1600 | 500 | ||
ZBW-S225 | 225 | 342 | 900×800×1900 | 530 | ||
ZBW-S250 | 250 | 380 | 1100×800×2100 | 580 | ||
ZBW-S320 | 320 | 486 | 1100×800×2100 | 630 | ||
ZBW-S400 | 400 | 608 | 1100×1000×2200 | 750 | ||
ZBW-S500 | 200 | 760 | 1200×1000×2200/2 | 870 | ||
ZBW-S600 | 600 | 912 | 1200×1000×2200/2 | 980 | ||
ZBW-S800 | 800 | 1215 | 1400×1000×2200/3 | 1100 | ||
ZBW-S1000 | 1000 | 1512 | 1400×1000×2200/3 | 1300 | ||
ZBW-S1200 | 1200 | 1823 | 1400×1000×2200×/3 | 1450 | ||
ZBW-D3 | 3 | One phase 176V-264V | One phase 220V±7% Can be setup | 13.6 | 250×500×500 | 20 |
ZBW-D5 | 5 | 22.7 | 250×500×500 | 28 | ||
ZBW-D10 | 10 | 45.4 | 350×600×600 | 50 | ||
ZBW-D20 | 20 | 91 | 350×600×600 | 80 | ||
ZBW-D30 | 30 | 136 | 660×600×1400 | 100 | ||
ZBW-D50 | 50 | 227 | 660×660×1400 | 140 |
Specifications | SBW series of high-power automatic compensation | ZBW series microcomputer compensation of non-contact |
principle | Carbon Brush-rely on the surge in themobile transformer change compensation voltage transformer secondary winding maintain out-put voltage stability. There Carbon Brush, contacts, mechanical transmission. | By microprocessors and large-scale logiccircuits (PLD)ex-change control in the AC voltage is switched off 0.1 of a combination of transformer switching compensation main output voltage stability. No Carbon Brush, No contact, no machinery, the three-phase transfer. |
Response time | Slower(about 200 ms) | Express(<10ms) |
Voltage adjustment rate | Slow(20V/S,V per second adjustment20V ) | Express(20%jump voltage, voltage stability to the center)of time<10ms) |
Three-phase imbalance of |
EC does not have three-phase voltage-automatic balance function | Automatic three-phase voltage balance, the three-phase transfer |
Starting ease impact |
Non-conventional products | A functional again from the first regulator |
Automatically boot | Non-conventional products | No, one bailiffs have Shou function automatically boot |
Anti-harmonic function |
There is no such function | Voltage, current acquisition have anti-harmonic function, load equipment in the power grid or serious harmonic interference, the output voltage can still, maitain stability, current measurement can still maintain accurate |
Fault Protection | Cut Output | Protection time soon, cutting output or uninterrupted automatically converted to bypass work |
Bypass function | The manual bypass | There are (and can automatically bypass uninterruped) |
Periodic maintenance |
Regular maintenance | Maintenance-free |
Parameters | Pointer | Various parameters TRMS figures show |
Parameter settings | Simulation potentiometer adjustments, or may not ses | Digital touch key settings(convenient, humane) |